search
Search

Enter keywords to search for products, blog posts, and more.


Home > Ceiling Mounted Dehumidifier (GDH-CE56)

Ceiling Mounted Dehumidifier (GDH-CE56)
Ceiling Mounted Dehumidifier (GDH-CE56)

Ceiling Mounted Dehumidifier (GDH-CE56)

Product Overview
The GDH-CE56 is a high-capacity ceiling mounted dehumidifier designed for concealed installation in demanding commercial and industrial spaces. Measuring 800 × 496 × 400 mm with a compact 23 kg lightweight structure, it delivers an impressive 56 L/day moisture extraction rate (at 30 °C / 80% RH) and 550 m³/h powerful airflow. Engineered specifically for areas where floor space is at a premium or aesthetics matter, this model utilizes eco-friendly R290 refrigerant to meet the most stringent international environmental compliance standards while efficiently covering spaces up to 130 m².

Why Choose the GDH-CE56 Format
Unlike standard portable units that clutter floor space and disrupt workflows, the GDH-CE56 integrates directly into the ceiling void or HVAC ducting. B2B buyers select this high-capacity model for high-moisture environments requiring uncompromised floor utility or clean aesthetics—such as commercial warehouses, production workshops, archives, basements, indoor pools, and drying rooms. Its overhead design guarantees even airflow distribution and isolated acoustic performance.

Core Build Points

  • 56 L/day extraction capacity at 30 °C / 80% RH with 550 m³/h high-speed external fan
  • 130 m² large-scale recommended coverage area per unit
  • Eco-friendly R290 refrigerant with a highly regulated 130g factory-sealed charge
  • Dual pure copper tubes equipped with advanced titanium foil fin treatment
  • Heavy-duty thickened sheet metal housing with moisture-proof conformal coating
  • Continuous direct drain pipe connectivity (tankless automated operation)
  • Intelligent LCD touch screen controller with ±3% RH precision and time switch
  • Automated hot-gas defrost and robust fault self-protection logic (≤50 dB(A))
  • Comprehensive OEM/ODM support — MOQ 10 units per batch

For compact layouts with lower clearance, refer to the GDH-CE38 low-profile model. For continuous ultra-low humidity processing below 5 °C, browse our industrial rotary dehumidifier range.

Technial Parameters

SpecificationGDH-CE56
Dehumidification Capacity (30°C / 80% RH)56 L/day
Power Supply220V / 50Hz
Rated Power850 W
Noise Level≤50 dB(A)
Airflow550 m³/h
Working Humidity Range30% – 80% RH
Recommended Coverage Area130 m²
Working Temperature5 – 38 °C
Drainage MethodDrain Pipe (continuous plumbed configuration, no water tank)
Product Dimensions (L × W × H)800 × 496 × 400 mm
Packing Dimensions850 × 520 × 450 mm
RefrigerantR290 (130 g factory charge)
Net Weight23 kg

Product Details

Where the GDH-CE56 Excel Most

The GDH-CE56 is meticulously scaled to provide precision humidity regulation across spaces up to 130 m². It serves as an optimal solution for industrial warehouses, electronic workshops, pharmaceutical archives, high-capacity storage rooms, commercial basements, bank vaults, switchgear rooms, and commercial garages. With its 56 L/day capacity and powerful 550 m³/h airflow, it easily controls large latent moisture loads stemming from ambient infiltration, concrete slab off-gassing, or industrial processes.

For extensive manufacturing halls or highly compartmentalized facility blueprints, multi-unit distributed deployment is the recommended industry approach. Distributing several GDH-CE56 units across designated zones ensures optimal air mixing, uniform vapor pressure deficit (VPD) control, and systemic redundancy, outperforming a single oversized air handling plant without requiring expensive structural duct refitting.

The Hidden Ceiling Advantage: Engineering Spatial Efficiency

Integrating a high-capacity dehumidifier directly into the ceiling plenum delivers clear structural and operational pay-offs compared to standalone mobile hardware:

  • Zero Floor Footprint: The GDH-CE56 liberates valuable industrial workspace. Standalone units capable of extracting 50L+ typically command substantial floor footprints plus critical perimeter clearance zones for intake air and maintenance access.
  • Visual & Workflow Integration: The machine is completely hidden from sight. The only visible components within the workspace are the low-profile ducted intake and discharge grilles, which align seamlessly with standard commercial ceiling diffusers.
  • Enhanced Acoustic Comfort: Operating noise is structurally isolated. While the raw unit maintains a low ≤50 dB(A) acoustic envelope, standard commercial drop ceilings provide supplementary sound attenuation, lowering in-room noise by an extra 4–6 dB(A).
  • Simplified Maintenance Routing: Engineers can access the unit directly via removable ceiling panels. This setup avoids interrupting facility operations or displacing floor equipment during routine filter checks.

400 mm Cabinet Height & Structural Fitment Criteria

The GDH-CE56 features a robust horizontal housing with a cabinet height of 400 mm. This dimension dictates the minimum void height required for clear concealed installation. In standard industrial setups, commercial basements, or modern warehouses with drop ceilings, a clearance depth of at least 450 mm is recommended to comfortably accommodate structural mounting hangers, vibration isolation brackets, and duct elbows.

Before executing installation, contractors must audit the ceiling plenum to ensure sufficient clear spacing, factoring in pre-existing building infrastructure such as fire sprinkler mains, electrical cable trays, and primary structural beams. Its 23 kg net weight ensures safe suspension using standard M8 or M10 threaded rods hooked into concrete anchors.

Dual Pure Copper Tubes with Premium Titanium Foil Fins

At the heart of the GDH-CE56 refrigeration circuit is a highly resilient heat exchanger constructed from dual pure copper tubes integrated with premium titanium foil fins. This dual-circuit layout dramatically expands the active cooling surface area within a optimized cabinet profile, facilitating accelerated condensation cycles and elevated thermal transfer efficiency.

Crucially, the titanium foil fin treatment delivers superior chemical and corrosion resistance far surpassing the standard hydrophilic aluminum coatings found on light-duty portable units. Standard aluminum fins operating in harsh industrial environments or indoor pools often suffer from oxidation and pitting within 3–5 years, leading to a steady drop in extraction capacity. Our titanium foil finish safeguards the core structure against corrosive moisture and airborne particulates, extending the operational lifecycle to 10–12 years under continuous heavy-duty cycles.

R290 Eco-Friendly Refrigerant: Compliance & Performance

The GDH-CE56 is powered by R290 (propane) refrigerant, utilizing a factory-sealed 130g charge. Boasting an ultra-low Global Warming Potential (GWP = 3) and zero Ozone Depletion Potential (ODP = 0), R290 stands as the premier eco-friendly alternative to legacy hydrofluorocarbons (HFCs) like R410A. This makes the unit fully compliant with the latest global environmental mandates, including the EU F-gas Regulation (EU 2024/573) and the US EPA SNAP program.

Furthermore, the 130g charge configuration falls strictly below the rigid 150g flammability threshold defined by international safety standards for sealed commercial refrigeration systems. This careful calibration eliminates the need for expensive explosion-proof electrical enclosures while ensuring the machinery remains fully compliant for unrestricted import, sale, and installation across eco-conscious markets.

Automated Plumbed Drainage & Durable Construction

Given its 56 L/day capacity, the GDH-CE56 bypasses internal collection tanks entirely in favor of an automated, continuous plumbed drain pipe framework. Condensate smoothly migrates out via a heavy-duty rear drainage connector. For standard overhead layouts, this allows for straightforward gravity drainage to a nearby wastewater riser.

For specialized basements or deeper sub-floors where gravity lines sit above the ceiling void, the unit pairs perfectly with an external commercial condensate pump (available via our OEM factory bill of materials). Structurally, the unit features a 1.0 mm cold-rolled steel housing with protective electrostatic powder coating, while internal electronics are treated with a moisture-proof conformal coating to resist short-circuits in high-humidity zones.

B2B Industrial Customization: OEM/ODM Services

As a Tier-1 Chinese industrial dehumidifier manufacturer, we offer comprehensive OEM/ODM customization services starting from a low MOQ of 10 units per contract. Our standard OEM catalog covers custom corporate branding, tailored cabinet colors, localized electrical plug configurations, and custom multilingual packaging artwork. For large-scale installation and engineering channels, we specialize in supplying factory-bundled installation kits, including extended power cords, commercial condensate pumps, custom structural suspension brackets, and replacement filter sets.

Our advanced ODM services cater to highly specialized project briefs, including Modbus RTU or BACnet protocol integration for central Building Management Systems (BMS), dual-frequency 50Hz/60Hz fan assemblies, integrated HEPA filtration modules for cleanrooms, and accelerated routing for localized safety certifications (such as ETL, SAA, or GS). Standard factory lead times average 25–35 days from technical sign-off, shipped FOB Ningbo or Shanghai port.

FAQs

What minimum ceiling clearance is mandatory for installing the GDH-CE56?

The GDH-CE56 cabinet features a precise vertical height of 400 mm. To facilitate professional installation, including structural hanger rods, vibration isolation dampening pads, and localized duct routing, a minimum clear ceiling void depth of 450 mm is required. Contractors must verify that pre-existing infrastructure like piping or conduits does not compromise this clearance at the designated mounting location.

What are the primary operational benefits of the R290 refrigerant in this unit?

R290 is an eco-friendly natural refrigerant featuring an ultra-low Global Warming Potential (GWP = 3) and zero ODP, making the unit fully compliant with strict international environmental laws like the EU F-gas mandate. Performance-wise, its superior thermodynamic properties enable faster heat exchange and lower energy consumption. Furthermore, the 130g charge is safely below the international 150g flammability threshold for commercial equipment.

How does the titanium foil fin treatment improve heat exchanger longevity?

Unlike conventional hydrophilic aluminum coatings that degrade under sustained high-humidity exposure or corrosive environments, the premium titanium foil fin treatment provides a dense, oxidation-resistant barrier. This specialty coating prevents core pitting, maximizes continuous thermal efficiency, and extends the heat exchanger's operational lifespan to 10–12 years under demanding commercial or industrial workloads.

Can the GDH-CE56 handle continuous drainage without an integrated pump?

Yes, the unit relies on a continuous plumbed drain pipe configuration that utilizes natural gravity drainage, which is highly efficient if the wastewater line runs below the ceiling level. For specialized layouts where the drain line is situated above or level with the ceiling void, an external commercial condensate pump can be easily integrated and factory-bundled within your OEM order.

Is the intelligent control system accessible when the unit is hidden in the ceiling?

Absolutely. While the main body houses the core diagnostic electronics and an auto-defrost system, the unit connects to a tethered intelligent LCD touch screen controller. This controller can be mounted on a convenient wall surface or workstation area up to several meters away, providing operators with seamless access to real-time humidity tracking (±3% RH accuracy) and timer configurations.

What options are available for OEM/ODM brand customization and what is the MOQ?

Our factory provides comprehensive commercial OEM/ODM services starting from a baseline MOQ of 10 units. Customization capabilities include proprietary logo placement, bespoke housing paint finishes, specialized regional plug configurations, and custom packaging. Advanced engineering customization—including Modbus RTU BMS integration or custom brackets—is quoted on a per-project basis with a standard 25–35 day lead time.

Designing a high-capacity commercial or industrial climate control project? Submit your detailed architectural floor plans, ceiling void clearance metrics, local power standards, and target humidity requirements to our technical division. Our engineering specialists will draft a comprehensive multi-unit deployment layout, complete with calculated electrical loads and specialized drainage blueprints within 24 working hours. Technical CAD drawings and export certification packages are fully accessible prior to purchase validation.

Amy

General Manager